1. Brief introduction:
Fixed C2H6O ethanol gas detector uses high precision and fast response sensor ,test ethanol gas leak concentration by natural diffusion,when gas leakage more than alarm points(normal set 25%,user can set flexibly),the detector will send sound and light alarms from alarm light.LCD display (No display and LED display are available),4-20mA and RS485 Modbus signal output,save 3000 alarm records,CE and ATEX approved.
2. Detailed introduction:
Ethanol gas detector is designed to detect and monitor ethanol gas levels in real-time. The fixed installation of this device ensures continuous monitoring of ethanol gas concentration, making it an ideal solution for the safe operation of facilities where ethanol gas is produced, stored or used, such as distilleries, bioethanol plants, and laboratories..
The device provides reliable results and ensures the safety of personnel and property. Its advanced features include a LCD display that provides real-time concentration levels in ppm or % LEL, configurable alarm setpoints, and adjustable sensitivity levels. The gas detector is easy to operate with a simple calibration process, low power consumption, and rugged construction.
With the increasing use of ethanol in various industries, it is imperative to have a reliable ethanol gas detector in place. Our device ensures that ethanol gas levels are continuously monitored, allowing for timely action in case of an emergency and ensuring a safe and secure working environment.
3. Features:
LCD display in English
Water proof,dust proof and explosion proof
High precision and fast response sensor
Detect ethanol gas by natural diffusion
Adjustable two alarm points
DC12V-24V working power
4-20mA or RS485 Modbus signal output
3A relay for solenoid valve or fan etc devices
Sound and light alarm from alarm light
Save 3000 alarm records
Supports connect with alarm control panel
CE ATEX CNEX ISO9001 explosion proof certificates
100% strictly inspection before package
4. Technical parameters:
|
Product name |
Fixed ethanol gas detector with alarm light |
|
Size and weight |
144*190*91mm, 1600g |
|
Sensor types |
Catalytic combustion method |
|
Destination gas |
Ethanol C2H6O |
|
Measure range |
0-100%lel |
|
Working pattern |
Continuous work |
|
Working voltage |
DC12-24V |
|
Display |
LCD display |
|
Alarms(Optional) |
Intelligent sound and red light alarms |
|
Output signal |
4-20mA or RS485 Modbus |
|
Temperature humidity |
- 20 ℃ ~ 50 ℃,15% ~ 90% RH (No condensation) |
|
Explosion-proof number |
CE10 1084 |
|
Explosion-proof marks |
Exd II CT6 |
|
Transmission distance |
< 1000 m |
|
Certificate |
CE, ATEX, CNEX, ISO9001 |
|
Optional |
Multi gas alarm controller |



5. Application:
This fixed ethanol gas detector widely be used in chemical industry, mines, tunnels, refinery, leather factory, laundry,hospital, production plant and soon on,detect ethanol concentration or leakage,to effectively prevent the occurrence of poisoning.
6. Calibration ethanol gas detector:
Note:
1. Zero correction can be made after starting the instrument and finishing the initialization.
2. Oxygen can enter the "Gas Calibration" menu under standard atmospheric pressure. The calibration display value is 20.9%vol. Do not perform zero correction operations in the air.
3. Supports 3-point calibration. If there is only one calibration gas, please set the other calibration points to 0 and clear that calibration point.
Step 1: Zero correction
In the main menu interface, press the left button to select the "Device Calibration" function, and then press the right button to enter the menu of input calibration password through the combination of buttons or remote control key, select items zero correction function, and then press right button to enter zero calibration menu, through left button to choose the type of gas, then press right button to enter selected gas zero cleaning menu, determine the current gas 0.
Step 2:Gas calibration
Turn on the calibration gas. After the displayed value of the gas is stable, enter the main menu and select the calibration selection menu. The specific operation method is Step 1 of zero calibration.
Select the function item Gas Calibration, press the right button to enter the calibration gas selection interface, selecting the gas type to be calibrated press the right button to enter the calibration point selection interface. If the calibration point is empty, it will display ------.
Press the left button again to enter the standard gas concentration setting interface,.Then use the left and right buttons to set the concentration value of the calibration gas. Assuming that the calibration is now, the concentration value of the calibration gas is standard gas.
After the calibration is successful, if the displayed value of the gas is not stable, you can repeat calibration. If the calibration fails, please check whether the concentration of the standard gas is consistent with the calibration setting value. After the gas calibration is completed, press the right button to return to the gas type selection interface to calibrate other points.
After the gas calibration is completed, press the menu until to return to the gas detection interface, or automatically exit the menu and return to the gas detection interface after the countdown interface reduces to 0 without pressing any button.