Can natural gas detector be used in harsh environment?

Nov 06, 2019 Leave a message

Can natural gas detector be used in harsh environment?

Natural gas alarm detectors used in industrial field face to all kinds of harsh environments and atmosphere, especially the stationary sensors, long-term continuous operation, explosion proof and the limitation of the power supply capacity, therefore it is very strict for the technical indicators. Usually judge index and performance of gas detector from the following several aspects.

 1. Detection range and resolution; 

 2. Detection accuracy and repeatability; 

 3. Stability and zero point drift; 

 4. Response time and recovery time; 

 5. Selectivity and anti-interference ability; 

 6. Safety and explosion-proof performance; 

 7. Power consumption; 

 8. Ability to resist the influence of environment (temperature and humidity); 

 9. Anti-poisoning ability and life span; 

 10. Interchangeability and convenient maintenance.

gas sensor and controller

The installation position, Angle, protective measures and system wiring of natural gas alarm should prevent electromagnetic interference. Various factors need to consider before using,electromagnetic environment on the combustible gas alarm there are three main ways of influence: electromagnetic interference in the air, power supply and other input and output line of the narrow pulse group and human static electricity. For example, when the combustible gas alarm is close to the installation of air conditioning, it will cause deviation in the detection of the system. The distance between detection lines and power lines, lighting lines and other strong electric lines is small, and without anti-electromagnetic interference measures, the system will also produce detection deviation.

User should pay attention to the factors easily causing fault in the process of using combustible gas alarm, such as dust, high temperature, humidity, rain, etc. When the place where combustible gas alarm is installed needs to install an exhaust fan, if the exhaust fan is set adjacent to the combustible gas detector, the leaking combustible gas will not be able to fully diffuse to the vicinity of the combustible gas alarm. 

Users should also pay attention to avoid high temperature, high humidity, steam, smoke can reach the place. Do not place or hang objects on the detector. Installed combustible gas alarm can not arbitrarily move the position of the device. 

Users use the combustible gas alarm as far as possible to select the sensor probe replaceable product, in order to facilitate the use. Cause not timely detection. 

Users should also pay attention to the setting of combustible gas alarm in explosion-proof places. For example, explosion-proof type combustible gas alarm should be selected in class a workshop emitting combustible gas, and its explosion-proof level should not be lower than the corresponding explosion-proof level required by the current code.

controller install with sensor valve and ventilator