video
LPG Leak Detector

LPG Leak Detector

1. Natural diffusion type
2. Supports 4-20mA or RS485 signal output
3. LED digital display
4. Two adjustable alarm points
5. Industrial explosion-proof,CE and ATEX certificates

Product Introduction

1. Brief introduction

LPG leak detectors is their ability to detect leaks before they become problematic. When a leak is present, the detector will alert the user, allowing them to quickly address the issue and prevent a potentially hazardous situation from occurring. This can help to protect both people and property from harm.

 

2. Detailed introduction

Fixed LED style lpg leak detector is an efficient, accurate, safe and reliable gas detection instrument, which is widely used in the monitoring of various types of gas equipment, real-time recording of changes and the construction of alarm systems.

 

This detector adopts the latest digital technology, which can detect gas concentration in real time with high speed and high precision and automatically calculate the group concentration, effectively preventing gas leaks, explosions and other safety accidents, and creating a more comfortable and safer living environment for people. .

 

In addition, this LPG gas detector also has functions such as self-detection, self-calibration and fault self-protection to ensure its long-lasting reliability and system stability. Moreover, the detector is easy to use and simple to operate, and does not require professional technicians to install and debug.

 

3. Technical parameters

Product name

Fixed lpg leak gas detector with alarm light

Size and weight

144*190*91mm, 1600g

Sensor types

Catalytic combustion method

Destination gas

LPG,LEL,H2,alcohol

Measure range

0-100%lel,resolution is 1%lel

Working pattern

Continuous work

Working voltage

DC12-24V

Display

LED digital display

Alarms(Optional)

Sound and red light alarms

Output signal

4-20mA or RS485 Modbus

Temperature humidity

- 20 ℃ ~ 50 ℃,15% ~ 90% RH (No condensation)

Explosion-proof number

CE10 1084

Explosion-proof marks

Exd II CT6

Transmission distance

< 1000 m

Certificate

CE, ATEX, CNEX, ISO9001

Optional

Multi gas alarm controller

Lpg Leak Detector 

Lpg Leak Detector  price

Lpg Leak Detector  suppliers

4. Features:

LED digital display in English

Water proof,dust proof and explosion proof

High precision and fast response sensor

Detect LPG CH4 H2 etc combustible gas leakage

Adjustable alarm points

DC12V-24V working power

4-20mA or RS485 Modbus signal output

3A relay for solenoid valve or fan etc devices

Two normal open or normal close is available

Sound and light alarm from alarm light

Supports connect with alarm controller

Aluminum shell material with high strength, heat resistance and corrosion resistance

CE ATEX CNEX ISO9001 explosion proof certificates

100% strictly inspection before package

 

5. Application

Fixed combustible LPG leak detectors are widely used in industry, chemical industry, petroleum, natural gas, electric power and other industries. Its main function is to monitor the concentration of combustible gases in the air and alarm in time when abnormal concentrations are found to ensure the safety of work and production sites. In order to ensure the normal operation of the detector, the following are some installation and use scenarios.

 

First, fixed combustible gas detectors should be installed in areas where combustible gas leaks may exist. This includes places like pipelines, storage tanks, tank farms, etc. In addition, the height of the detector from the ground should be set according to the gas density, usually more than 30cm from the ground at the lowest air concentration. In order to obtain better detection results, the detector should be installed away from obstructions and other interference factors.

 

During the use of fixed combustible gas detectors, regular inspection and maintenance are required. Especially measurement sensors are calibrated to ensure their accuracy and stability. When replacing sensors and other components, you must follow the manufacturer's instructions to avoid safety accidents caused by misoperation.

 

During the installation process, appropriate fixed combustible gas detectors should be selected according to different usage scenarios and needs. For high-risk industries, products with high sensitivity and strong reliability should be selected. At the same time, the detector used should comply with relevant national safety standards, such as ISO, CE and other certifications.

 

In short, fixed combustible gas detectors are important equipment to ensure personnel and production safety. Detailed planning and installation must be carried out before use. When using, attention should be paid to regular maintenance and testing to avoid missed detection or false alarms. Only in this way can the safety of personnel and equipment be effectively ensured.

 

Contact:

Welcome to know more information from below

Email:sallie@huafankj.com

WhatsApp:+86 18291437464

 

 

Hot Tags: lpg leak detector, China lpg leak detector manufacturers, suppliers

Send Inquiry

whatsapp

Phone

E-mail

Inquiry

Bag